Extend service life of QJMC 2-inch & 3-inch gasoline pumps with full maintenance schedule: engine oil change cycle, spark plug adjustment, air filter cleaning & long-term storage tips.

Engine oil protects internal moving parts; oil shortage will burn the engine permanently:
1).Daily inspection: Check the oil level every morning before starting the pump, ensure oil stays within standard scale;
2).First oil replacement: For brand-new pumps, replace oil after 1 month or 20 running hours (whichever arrives first);
3).Regular oil replacement: After the first change, replace SAE 10W-30 oil every 6 months or 100 cumulative working hours;
4).Refill volume: 0.6 Liter after draining old oil completely.

1).Remove the spark plug regularly for visual inspection;
2).If thick carbon accumulates on electrodes, clean carbon dirt thoroughly;
3).Adjust the electrode gap to standard 0.7mm ~ 0.8mm;
4).Directly replace the spark plug if damaged, cracked or with abnormal ignition.

Blocked air filter leads to insufficient combustion, increased fuel consumption and engine power drop:
1).Dismantle the air filter element from the engine housing;
2).Wash the filter with kerosene and air-dry it completely (no residual kerosene);
3).Soak the filter with a small amount of engine oil, then squeeze out redundant oil;
4).Reinstall the filter element; replace broken filters immediately to avoid dust entering the cylinder.
1).Check all hose clamps, connectors, sealing washers and gaskets for looseness, aging or cracking before each use;
2).Clean the strainer foot valve after every workday to remove silt, weeds and debris blocking water intake;
3).Inspect mechanical seal, impeller and internal gaskets periodically for water leakage or wear; replace worn spare parts timely.
1).Drain all residual water inside the pump cavity to prevent rust and frost crack in cold weather;
2).Run the engine until the fuel tank is empty to avoid stale gasoline clogging the carburetor;
3).Replace engine oil before storage to prevent acid corrosion from old oil;
4).Store the pump in a dry, ventilated room away from rain, dust and direct sunlight;
5).Cover inlet & outlet ports to stop dust and insects entering the pump body.